About Xinya

A power cable manufacturer that supplies complete cable packages for solar plants.

01

Cable makers first

Xinya Power Cables started with power cables for utilities. Solar EPCs asked us for the DC side as well — so we now supply everything from the module lead to the 33 kV collector circuit as one package.

02

Built to the solar standards

Electron-beam cross-linked insulation, tinned class 5 conductors and a test regime built around EN 50618, IEC 62930 and UL 4703 — with documents for each batch.

03

Engineering support

Our engineers check voltage drop, current derating and DC losses, prepare the cable schedule and labels for your strings — in 13 languages.

1.5 kVDC rating · EN 50618 / IEC 62930
120 °Cconductor temperature, 20,000 h
25 yrdesigned outdoor service life
13languages of engineering support

What we commit to

  • Honest data sheets with real conductor resistance
  • Full length on every coil and drum
  • Fast, documented quotations
  • After-sales support across time zones
How it is made

How a solar cable is made.

Six production steps decide whether a PV cable survives 25 years outdoors: stranding, extrusion, electron-beam cross-linking, spark testing, laboratory checks and packing.

Stranding fine tinned-copper wires
Stranding fine tinned-copper wires
Insulation and sheath extrusion
Insulation and sheath extrusion
Electron-beam cross-linking
Electron-beam cross-linking
Spark test and coiling
Spark test and coiling
UV, tensile and ageing tests
UV, tensile and ageing tests
Coils and drums ready to ship
Coils and drums ready to ship
Quality & standards

Every length tested before it ships.

Routine tests on every production length, sample tests on every batch, and construction to EN 50618, IEC 62930 and UL 4703.

Tests on every batch

  • Conductor resistance at 20 °C
  • Spark test on insulation and sheath
  • AC / DC voltage withstand
  • Insulation resistance at 90 °C
  • Dimensions and eccentricity
  • Hot-set test (cross-linking)
  • Tensile and elongation before and after ageing

Test reports and certificate copies are shared with your quotation — ask for the documents your project requires.

Cable test laboratoryCable test laboratory

Standards we build to

  • EN 50618H1Z2Z2-K · 1.5 kV DC
  • IEC 62930PV cables · 1.5 kV DC
  • UL 4703PV Wire · 600 V – 2 kV
  • 2PfG 1169PV1-F · 1.8 kV DC
  • IEC 62852DC connectors · 1,500 V
  • IEC 60502AC & MV power cables
  • IEC 60332-1-2Flame propagation
  • IEC 60754 · 61034Halogen-free, low smoke

From inquiry to delivery

A clear path, with an engineer — not a script — at every step.

  1. 1 / 5Inquiry

    Send cable type, sizes, colours and lengths. Reply within one working day.

  2. 2 / 5Engineering

    Sizing check, cable schedule, drum lengths and labelling plan.

  3. 3 / 5Production

    Stranding, extrusion, cross-linking and assembly with progress photos.

  4. 4 / 5Testing

    Routine tests on every length, third-party inspection welcome.

  5. 5 / 5Delivery

    Coils on pallets or drums, documents and shipping marks per project.

Planning a solar project?

Send the array layout, string current and route lengths. You get a cable schedule, sizing check and quotation within one working day.