Applications

Choose your project type — we match DC, AC and MV cables and assemblies into one cable schedule.

Applications

From the module to the grid — every cable, one supplier.

Pick a project type and follow the power through the plant, with the matching cable on every section.

  1. 1PV modules & stringsH1Z2Z2-K Solar Cable EN 50618, 1.5 kV DC
  2. 2String combiner boxAluminium-Alloy Solar DC Cable 1.5 kV
  3. 3Central / string inverterAC Inverter Cable 0.6/1 kV XLPE (Cu / Al)
  4. 4Step-up box transformer33 kV MV Collector Cable, XLPE Aluminium / Copper
  5. 5Plant substation & grid

Module leads and H1Z2Z2-K string cables run to the combiner box; aluminium DC home-runs feed the inverter, AC cable connects the step-up transformer and 33 kV collector cable carries the power to the plant substation.

Assemblies & OEMY-Branch Solar Cable Harness
Inside a solar cable built for 25 years. H1Z2Z2-K · EN 50618
EN 50618 · IEC 62930

Inside a solar cable built for 25 years.

A PV cable lives on a roof or tracker in full sun, frost, rain and wind for decades. Every layer of our DC cable is chosen for that life — and tested for it.

  1. Tinned copper, class 5

    Fine tinned strands stay flexible on the tracker and resist corrosion in humid and coastal air.

  2. E-beam cross-linked XLPO

    Electron-beam cross-linked insulation and sheath: 120 °C conductor rating, halogen-free, UV and ozone resistant.

  3. 1.5 kV DC, double insulated

    Rated 1.5/1.5 kV DC (1.8 kV max.) for today's 1,500 V string designs, class II safety.

  4. Assemblies to your drawing

    Extension leads, Y-branches and complete harnesses cut, crimped, tested and labelled per string.

FAQ

Questions buyers ask

Short answers from our engineers. Ask anything else in the inquiry form.

What is the difference between H1Z2Z2-K and PV1-F?

H1Z2Z2-K is the current European standard cable (EN 50618) rated 1.5 kV DC; PV1-F is the older TÜV 2PfG 1169 design rated 1.0 kV AC / 1.8 kV DC between conductors. New 1,500 V plants usually specify H1Z2Z2-K or IEC 62930.

Should I use 4 mm² or 6 mm² solar cable?

It depends on string current and length. 4 mm² suits most residential strings; for long runs or modules above about 13 A, 6 mm² keeps voltage drop below 1–1.5%. Our sizing tool checks both voltage drop and current rating in seconds.

Can I use aluminium cable on the DC side?

Yes, for combiner-box to inverter home-runs of 16 mm² and above. Aluminium lowers cost and weight; it needs about 1.6 times the copper cross-section and terminals rated for aluminium. String cables stay tinned copper.

Do you supply UL 4703 PV wire for the US market?

Yes: PV wire 600 V, 1 kV and 2 kV from 14 AWG to 500 kcmil, sunlight resistant and direct-burial rated, on 500, 1,000 or 2,500 ft reels.

What is the minimum order and lead time?

Standard colours and sizes start from one pallet of coils; drums and assemblies are made to order. Typical lead time is two to four weeks after confirmation — we confirm a firm date with every quotation.

Which documents come with the cables?

Routine test reports for each batch, a packing list with lengths per coil or drum, and certificate or type-test copies for the standards you specify. Third-party inspection before shipment is welcome.

Planning a solar project?

Send the array layout, string current and route lengths. You get a cable schedule, sizing check and quotation within one working day.