Solar PV cables & assemblies
EN 50618 and UL 4703 DC cables, aluminium DC cables, AC and MV collector cables, MC4 extension cables, Y-branch harnesses and connectors.
DC solar cables · H1Z2Z2-K 1×4H1Z2Z2-K Solar Cable EN 50618, 1.5 kV DCThe standard DC string cable for 1,500 V solar plants — 4 mm² and 6 mm² in stock colours.
- Cross-section1.5 – 240 mm²
- Rated voltage1.5 kV DC
- StandardEN 50618
DC solar cables · H1Z2Z2-K 2×4Twin-Core Solar Cable H1Z2Z2-K 2×4 / 2×6 mm²Plus and minus in one sheath — faster, neater rooftop runs.
- Cross-section2 × 2.5 – 2 × 10 mm²
- Rated voltage1.5 kV DC
- StandardEN 50618
DC solar cables · PV1-F 1×2.5PV1-F Solar Cable TÜV 2PfG 1169The classic 1,000 V PV cable for existing designs and repairs.
- Cross-section1.5 – 35 mm²
- Rated voltage1.0 kV AC / 1.8 kV DC
- Standard2PfG 1169
DC solar cables · H1Z2Z2-K AD8 1×4Floating PV Solar Cable, AD8 Water-ResistantMade to lie in water for years — for floating plants and wet ground.
- Cross-section1.5 – 240 mm²
- Rated voltage1.5 kV DC
- StandardAD8 · EN 50618
UL PV wire · PV Wire 2 kV 10 AWGUL 4703 PV Wire 600 V / 1 kV / 2 kVPhotovoltaic wire for NEC 690 arrays in North America.
- Cross-section14 AWG – 500 kcmil
- Rated voltage600 V / 1 kV / 2 kV
- StandardUL 4703
Aluminium solar cables · XY-PVAL 1×70Aluminium-Alloy Solar DC Cable 1.5 kVCut DC home-run costs by up to half on large plants.
- Cross-section16 – 400 mm² Al
- Rated voltage1.5 kV DC
- StandardIEC 62930
AC & MV collector cables · YJV / YJLV 0.6/1 kVAC Inverter Cable 0.6/1 kV XLPE (Cu / Al)From inverter to transformer — copper or aluminium, armoured or not.
- Cross-section1.5 – 630 mm²
- Rated voltage0.6/1 kV AC
- StandardIEC 60502-1
Made by Xinya
AC & MV collector cables · NA2XS(F)2Y 18/30 kV33 kV MV Collector Cable, XLPE Aluminium / CopperThe collector circuit between your box transformers and the plant substation.
- Cross-section50 – 630 mm²
- Rated voltage18/30 – 26/35 kV
- StandardIEC 60502-2
Cable assemblies · XY-EXT 4 mm²Solar Extension Cable with MC4 ConnectorsPre-crimped, tested leads in any length — plug in and go.
- Cross-section2.5 / 4 / 6 / 10 mm²
- Rated voltage1.5 kV DC
- StandardIEC 62852
Cable assemblies · XY-Y2 (2→1)Y-Branch Solar Cable HarnessParallel strings without a combiner on every row.
- Cross-section4 – 10 mm²
- Rated voltage1.5 kV DC
- StandardIEC 62852
Connectors & accessories · XY-MC4-1500MC4 Solar Connector 1,500 V DC, IP68Low-resistance connectors that match our cables.
- Cross-section2.5 – 10 mm²
- Rated voltage1.5 kV DC
- StandardIEC 62852
Planning a solar project?
Send the array layout, string current and route lengths. You get a cable schedule, sizing check and quotation within one working day.