Commercial & industrial rooftops
Fire-safe, halogen-free cables for factory and warehouse roofs.
Halogen-free, flame-retardant H1Z2Z2-K and twin-core cables in covered trays, plus 0.6/1 kV AC cable to the main switchboard — for roofs where fire codes, insurers and building owners look closely.
- Halogen-free, low smoke
- Twin-core for neat trays
- 0.6/1 kV AC to switchboard
From the module to the grid — every cable, one supplier.
Pick a project type and follow the power through the plant, with the matching cable on every section.
- 1Rooftop arrayTwin-Core Solar Cable H1Z2Z2-K 2×4 / 2×6 mm²
- 2String invertersAC Inverter Cable 0.6/1 kV XLPE (Cu / Al)
- 3AC combiner panelAC Inverter Cable 0.6/1 kV XLPE (Cu / Al)
- 4Building LV switchboard
- 5Utility grid
On a factory roof, H1Z2Z2-K or twin-core cable runs in covered trays to string inverters; 0.6/1 kV AC cable takes the output to the AC combiner panel and the building's main switchboard.
Assemblies & OEMY-Branch Solar Cable HarnessFeatured solar cables
DC solar cables · H1Z2Z2-K 1×4H1Z2Z2-K Solar Cable EN 50618, 1.5 kV DCThe standard DC string cable for 1,500 V solar plants — 4 mm² and 6 mm² in stock colours.
- Cross-section1.5 – 240 mm²
- Rated voltage1.5 kV DC
- StandardEN 50618
DC solar cables · H1Z2Z2-K 2×4Twin-Core Solar Cable H1Z2Z2-K 2×4 / 2×6 mm²Plus and minus in one sheath — faster, neater rooftop runs.
- Cross-section2 × 2.5 – 2 × 10 mm²
- Rated voltage1.5 kV DC
- StandardEN 50618
AC & MV collector cables · YJV / YJLV 0.6/1 kVAC Inverter Cable 0.6/1 kV XLPE (Cu / Al)From inverter to transformer — copper or aluminium, armoured or not.
- Cross-section1.5 – 630 mm²
- Rated voltage0.6/1 kV AC
- StandardIEC 60502-1
Cable assemblies · XY-EXT 4 mm²Solar Extension Cable with MC4 ConnectorsPre-crimped, tested leads in any length — plug in and go.
- Cross-section2.5 / 4 / 6 / 10 mm²
- Rated voltage1.5 kV DC
- StandardIEC 62852
Connectors & accessories · XY-MC4-1500MC4 Solar Connector 1,500 V DC, IP68Low-resistance connectors that match our cables.
- Cross-section2.5 – 10 mm²
- Rated voltage1.5 kV DC
- StandardIEC 62852
UL PV wire · PV Wire 2 kV 10 AWGUL 4703 PV Wire 600 V / 1 kV / 2 kVPhotovoltaic wire for NEC 690 arrays in North America.
- Cross-section14 AWG – 500 kcmil
- Rated voltage600 V / 1 kV / 2 kV
- StandardUL 4703
H1Z2Z2-K · EN 50618Inside a solar cable built for 25 years.
A PV cable lives on a roof or tracker in full sun, frost, rain and wind for decades. Every layer of our DC cable is chosen for that life — and tested for it.
- Tinned copper, class 5
Fine tinned strands stay flexible on the tracker and resist corrosion in humid and coastal air.
- E-beam cross-linked XLPO
Electron-beam cross-linked insulation and sheath: 120 °C conductor rating, halogen-free, UV and ozone resistant.
- 1.5 kV DC, double insulated
Rated 1.5/1.5 kV DC (1.8 kV max.) for today's 1,500 V string designs, class II safety.
- Assemblies to your drawing
Extension leads, Y-branches and complete harnesses cut, crimped, tested and labelled per string.
Planning a solar project?
Send the array layout, string current and route lengths. You get a cable schedule, sizing check and quotation within one working day.